Re: [PSUBS-MAILIST] Compression Fittings for thru-hull connectors



If the threads that you are talking about are in the motor housing for
motorguid or minakota they are 1-20 straight threads, both minakota and
motorguide use red locktight to seal the treads.  To remove the motor
support shaft from the motor use some heat to free up the locktight, but
use caution ...don't get the motor to hot that you burn up the inside
of the motor.  On the motors that I supply, I machine out the straight threads to a 3/4 Female National Pipe Thread, so that it will fit a comercialy available compresion fitting.

Roger
REJ & Co.
rjune@fuse.net
513-300-1189  
> 
> From: "Robert Carlson" <rob.carlson@verizon.net>
> Date: 2002/06/19 Wed PM 11:05:12 EDT
> To: "Personal_Submersibles@Psubs. Org" <personal_submersibles@psubs.org>
> Subject: [PSUBS-MAILIST] Compression Fittings for thru-hull connectors
> 
> I'm using a standard compression fitting for cable thru hull connectors
> but I'm having the darndest time trying to match the threads with a tap.
> I assumed they were NPT (i.e. pipe thread) but was told that they have
> their own thread type.  Can anyone help me on a source for taps to
> thread a hole for these threads? 
> 
> Rob Carlson
> 
> 
> 

Roger June
REJ and Company
rjune@fuse.net
513-300-1189
Title: Compression Fittings for thru-hull connectors

I'm using a standard compression fitting for cable thru hull connectors but I'm having the darndest time trying to match the threads with a tap.  I assumed they were NPT (i.e. pipe thread) but was told that they have their own thread type.  Can anyone help me on a source for taps to thread a hole for these threads?

Rob Carlson