Hi Vance,
 
Yes, understood.  They have a chart at Swagelok that tells you what wall thickness to use for the OD of the pipe and the pressure you want. 
 
i have the standard VBT design, i was going to use 1/2" SS tube for that part as per the plans (as its the vent as well) but at the correct thickness for 3000psi.  Then use thinner piping for the rest of it, again at the correct thickness for 3000psi.  Do you think that wont work now?  The through hull to the tank is sched 80, tank is as standard but with sched 80 air inlet pipe.
 
Thanks
James
On 28 December 2011 15:37, <vbra676539@aol.com> wrote:
James,
The original Kittredge design called for 135-150 psi system pressure and used 3/8" and 1/2" tubing to account for lower flow rates. If you are using a high pressure system, 1/4" SS tubing will do nicely. That said, you can't mix and match. Captain K's copper tubing system and VBT design are not strong enough for 3000 psi.
Vance


-----Original Message-----
From: James Frankland <jamesf@guernseysubmarine.com>
To: personal_submersibles <personal_submersibles@psubs.org>
Sent: Wed, Dec 28, 2011 5:28 am
Subject: [PSUBS-MAILIST] Msg For Dan H

Hi Dan,
 
Couldnt find your email so had to send this to the whole group.
 
Can you tell me what size piping you used for the HP air.  The smaller diameter one.  Looks like 3/8ths as per the plans?  With 0.032 wall?
 
Many thanks
James