On 29 November 2011 01:44, ojaivalleybeefarm @
dslextreme.com <ojaivalleybeefarm@dslextreme.com> wrote:
Hi All,
Getting ready to machine some thru hull shaft openings with O rings in the wall of the opening. Reading the parker o ring handbook it looks like the difference between the shaft diameter and the opening diameter is only .002" for a static O ring. But for dynamic o ring sealing it's a bit bigger difference in diameter of .005" Does that sound about right ? Also can machine tools for o rings be purchased off the shelf some place? Thanks in advance.