Hi Jim,
I remembered the discussion but forgot the details.
I used to hear all the time on Psubs that you test your sub to
twice your maximum
operating depth, unmanned, for an hour. This might not be a bad rule for
home builders
who aren't going through a certification inspection process; & may be
using blown domes
with their inherent stresses & weaknesses. Also there is the aging
process that must weaken
the hull, that should be accounted for. I'm still looking at making my hull
out of
fiberglass & there's a bigger margin of error required for that
material.
Alan
----- Original Message -----
Sent: Friday, December 10, 2010 12:31
PM
Subject: Re: [PSUBS-MAILIST] Design
depth
Alan,
My design depth is 600 ft. Operating depth is 300
ft. Therefore required test depth would be 375 ft. Failure depth
must be slightly deeper than 600 ft.
What test depth would you consider to be best based on the
above? I would have thought 400 ft. which isn't much more than
the standard. We had an online discussion of this in early
October. I'll forward my last post which includes the comments of
others.
Thanks,
Jim
In a message dated 12/9/2010 2:45:05 P.M. Central Standard Time,
alanjames@xtra.co.nz writes:
Thanks, that's a lot smaller margin than I thought, or would be
happy with myself. Alan ----- Original Message ----- From: "Jon
Wallace" <jonw@psubs.org> To:
<personal_submersibles@psubs.org> Sent: Friday, December 10, 2010
2:25 AM Subject: Re: [PSUBS-MAILIST] Design depth
>
> I believe for certification ABS requires the sub to be tested to
25% > above its maximum operating depth. So if your max op
depth is 100 feet > they would require it to pass testing at 125
feet. > > On 12/9/2010 2:44 AM, Alan James wrote: >>
Does ABS or ASME state what your operational depth should be in >>
relation to your crush depth? >> & if so is this different for
the view ports. >> I've read with fiberglass there is a 4x safety
factor where human life >> is concerned. >> Alan >
> > > >
************************************************************************ >
************************************************************************ >
************************************************************************ >
The personal submersibles mailing list complies with the US Federal >
CAN-SPAM Act of 2003. Your email address appears in our
database > because either you, or someone you know, requested you
receive messages > from our organization. > > If you want
to be removed from this mailing list simply click on the > link below
or send a blank email message to: >
removeme-personal_submersibles@psubs.org > > Removal of your
email address from this mailing list occurs by an > automated process
and should be complete within five minutes of > our server receiving
your request. > > PSUBS.ORG > PO Box 53 > Weare,
NH 03281 > 603-529-1100 >
************************************************************************ >
************************************************************************ >
************************************************************************ >
************************************************************************ ************************************************************************ ************************************************************************ The
personal submersibles mailing list complies with the US Federal CAN-SPAM
Act of 2003. Your email address appears in our database because
either you, or someone you know, requested you receive messages from our
organization.
If you want to be removed from this mailing list simply
click on the link below or send a blank email message to:
removeme-personal_submersibles@psubs.org
Removal of your email
address from this mailing list occurs by an automated process and should
be complete within five minutes of our server receiving your
request.
PSUBS.ORG PO Box 53 Weare, NH
03281 603-529-1100 ************************************************************************ ************************************************************************ ************************************************************************
|