[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [PSUBS-MAILIST] Design depth



Thanx Ian.

You are right. my design depth is my max operation depth.

I have assumed my design depth and also have calculated value of P.allowable. (minimum allowable failure pressure).

Can you suggest me the equation to find whether my P .allowable is good for my assumed depth?

Thanks again.

Regards,
JInesh

On Wed, Dec 8, 2010 at 5:45 PM, irox <irox@ix.netcom.com> wrote:

Hi Jinesh,

I am going to assume "design depth" is the same as maximum operational
depth, i.e.  the maximum depth you expect your submarine to operate at.

One approach is choose you operational depth based on how/where
you expect to use your submersible.  Once you have your operational
depth, you choose a safety factor (this various depending on the
designer, for some military subs this 1.25, for others higher).
The operational depth multiplied by the safety factor gives the
minimum failure depth.  You then design the pressure hull to failure
at some point deeper than this.

Hope that helped.

Can you post some information about your design and the requirements?

Thanks!
 Ian.


-----Original Message-----

From: jinesh gandhi

Sent: Dec 8, 2010 5:28 PM

To: personal_submersibles@psubs.org

Subject: [PSUBS-MAILIST] Design depth



Hello People,
  I am trying to carry out design calculations for the pressure Hull, according to the ABS guidelines. However, I couldn't find a section in the Guidelines suggesting how to find design depth for the sub.


I have been using Hull Calculator (found on psubs website) as a reference for my calculations.  Also, I've found different criteria (equations) to find the design depth on different sources.


Can anyone suggest me what equation to use to find the design depth?
TIA,Jinesh



************************************************************************
************************************************************************
************************************************************************
The personal submersibles mailing list complies with the US Federal
CAN-SPAM Act of 2003.  Your email address appears in our database
because either you, or someone you know, requested you receive messages
from our organization.

If you want to be removed from this mailing list simply click on the
link below or send a blank email message to:
       removeme-personal_submersibles@psubs.org

Removal of your email address from this mailing list occurs by an
automated process and should be complete within five minutes of
our server receiving your request.