[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [PSUBS-MAILIST] ABS pointer



On January 12, 2009 08:57:00 Jon Wallace wrote:
> Does anyone have a pointer to the ABS document that describes the
> thickness of material required when attaching a fitting, like a viewport
> thru-hull, into a hull penetration?  I believe that for less than 3/4
> inch material, the thru-hull fitting has to be at least the same
> thickness as the hull material, but I'm looking for confirmation from an
> ABS source.  I know ABS has that info somewhere.
>
> I did find references to "Part 4 Steel Vessels" in the ABS PVO
> documentation, but that then led me on a wild-goose chase since that
> pointed to another document, and then to another, and ultimately I could
> not locate the info.

Looking at the March '08 update of the ABS rules, the only thing I can find is 
in Section 7, stating:

"Penetrations are to be reinforced in accordance with Part 4, Chapter 4 of the 
Rules for Building and Classing Steel Vessels.  For external pressure the 
reinforcement need only be 50 percent of that required by the Rules and 
reinforcement pads are not to be used; all reinforcement is to be integral 
with shell and nozzle walls."

Looking into the quoted section of the steel vessel rules, I find 
reinforcement requirements in Part 4, Chapter 4, Section 1 - Appendix 1 Rules 
for Design, Item 7:  Openings and Reinforcements.  Specifically, 
Reinforcement Requirements are item 7.3.  There are about six pages of 
relevant material.

-Sean




************************************************************************
************************************************************************
************************************************************************
The personal submersibles mailing list complies with the US Federal
CAN-SPAM Act of 2003.  Your email address appears in our database
because either you, or someone you know, requested you receive messages
from our organization.

If you want to be removed from this mailing list simply click on the
link below or send a blank email message to:
	removeme-personal_submersibles@psubs.org

Removal of your email address from this mailing list occurs by an
automated process and should be complete within five minutes of
our server receiving your request.

PSUBS.ORG
PO Box 53
Weare, NH  03281
603-529-1100
************************************************************************
************************************************************************
************************************************************************