[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: [PSUBS-MAILIST] Steel Pipe Hull



Jay,
 
Thanks for pointing that out...it's an important note.  However, you can plug the data from the charts into the "hull Calculator" spread sheet located at
http://www.psubs.org/designguide/ABS_Hull_Calculation__Rev_12_17_2004.xls to get an idea of how different materials will react to external pressure.
 
Jon
 
-----Original Message-----
From: owner-personal_submersibles@psubs.org [mailto:owner-personal_submersibles@psubs.org]On Behalf Of Jay K. Jeffries
Sent: Sunday, January 28, 2007 7:00 PM
To: personal_submersibles@psubs.org
Subject: RE: [PSUBS-MAILIST] Steel Pipe Hull

Jon,

Please note these charts are for design of vessels that will experience an internal pressure not an external pressure like a submersible.  Other modes of failure such as buckling predominate in submarine hull design so these tables are not applicable for a PSUBS (other than the VBT or compressed air tanks).

R/J2

 

 

Respectfully,

Jay K. Jeffries

Andros Is., Bahamas

 

It is the mark of an educated mind to be able to entertain a thought without accepting it.
  -
Aristotle