Some of the plastic covers on wires are known to produce hydrogen cyanide when burned. Definetly not good.
Carl


Hugo Marrero wrote:

Gene,
There are several types of wiring insulation that are smoke-free / Halogen-free & self extinguishing. You should avoid any kind off PVC wiring at all costs as "its burning insulation creates copious amounts of smoke, and the insulation can turn to hydrochloric acid when exposed to moisture." (http://www.aviationtoday.com/reports/wiring7.htm). "Teflon is rated for continuous operation in temperatures from -60°C to 200°C and retains its exceptional toughness and Flexibility <javascript:openWindow('http://209.208.232.71/glossary.cfm?id=117', 'toolWin', true, 400, 400)> within this range. TFE Teflon is not degraded by chemicals which makes it ideal for use in harsh environments. Teflon is widely regarded as the ultimate high performance wire Insulation material for environments characterized by extreme thermal or chemical conditions." (http://www.alphawire.com/pages/175.cfm). While teflon is a less likely to cause problems in a sub, there are still precautions to take as even though it has excellent properties, it releases a series of toxic fumes at different tempreatures which could be very hazardous in an enclosed compartment such as a submersible. I am not sure, but don't quote me on it, but I believe that Teflon is not approved to use in Pressure Vessels for Human Occupation (PVHO). Some of the hazards of inhaling teflon-generated gases are at http://tuberose.com/Teflon.html The best is to stick with smoke-free halogen-free wiring such as that used on aircraft. On the safety side, a separate air supply for emergency breathing is advisable (required for ABS classed subs) for added safety. I hope this helps, Hugo

-----Original Message-----
From: owner-personal_submersibles@psubs.org [mailto:owner-personal_submersibles@psubs.org]On Behalf Of HUNTR2@aol.com
Sent: Thursday, May 27, 2004 3:34 AM
To: personal_submersibles@psubs.org
Subject: Re: [PSUBS-MAILIST] Copper wiring.

    As far as wiring goes....  is there a wire insulation that does not
    give off toxic gasses if it happens to get too hot during a short
    circuit situation?  This might be an important safety issue to keep
    in mind.  The flexibility of the fine strand copperwire sounds good
and makes sense otherwise. Gene Seus

--
IMPORTANT: This e-mail is intended for the use of the individual addressee(s) named above and may contain information that is confidential privileged or unsuitable for overly sensitive persons with low self-esteem, no sense of humour or irrational religious beliefs.

If you are not the intended recipient, any dissemination, distribution or copying of this e-mail is not authorised (either explicitly or implicitly) and constitutes an irritating social faux pas. Unless the word absquatulation has been used in its correct context somewhere other than in this warning, it does not have any legal or grammatical use and may be ignored.

No animals were harmed in the transmission of this e-mail, although a cat got sick and someone shot a duck. Those of you with an overwhelming fear of the unknown will be gratified to learn that there is no hidden message revealed by reading this warning backwards, so just ignore that Alert Notice from Microsoft.

However, by pouring a complete circle of salt around yourself and your computer you can ensure that no harm befalls you and your pets. If you have received this e-mail in error, please add some nutmeg and egg whites and place it in a warm oven for 40 minutes. Whisk briefly and allow to stand for 2 hours before icing.





************************************************************************
************************************************************************
************************************************************************
The personal submersibles mailing list complies with the US Federal
CAN-SPAM Act of 2003.  Your email address appears in our database
because either you, or someone you know, requested you receive messages
from our organization.

If you want to be removed from this mailing list simply click on the
link below or send a blank email message to:
	removeme-personal_submersibles@psubs.org

Removal of your email address from this mailing list occurs by an
automated process and should be complete within five minutes of receipt
of your request.

mailto:removeme-personal_submersibles@psubs.org

PSUBS.ORG
PO Box 311
Weare, NH  03281
603-529-1100
************************************************************************
************************************************************************
************************************************************************