[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [PSUBS-MAILIST] ASME PVHO



Hugh - looking through my references, I appear to only have a copy of ASME PVHO-1-2002.  I will have to order the newer code to see what the changes are.

Can you put that formula in context (i.e. what is it that you are trying to calculate)?

-Sean


On 31/10/2010 8:06 PM, Hugh Fulton wrote:

Hi Sean,

 

I am having problems with doing Q.A. on my shell for out of roundness.  This is an area which is fairly important to measure.

I have applied the 1% rule as a general tolerance but trying to comply and understand the PVHO caclcs.

 

ASME PVHO-1-2007 has a section:-

 

1-7.13.3 (e) (2)  Formula for c

 

c= 2.28(R/t)^0.54  cannot get under the required 2.8 with any normal measurements of a vessel .

 

Do you have any experience with this. 

My diameter is 48” and the shell thickness 5/16”  L is 15.75” 

Have you done any calcs on this area. 

 

Do/t for my purpose is 162 which falls within normal dimensions and under UG80.1 gives sensible answers.

 

Regards,

Hugh

 



__________ Information from ESET NOD32 Antivirus, version of virus signature database 5580 (20101031) __________

The message was checked by ESET NOD32 Antivirus.

http://www.eset.com