Today we have the first test runs of the drive system.
- Diesel runs 140 KW, 500-2500 rpm
- Maingear works,
- DC-Generator 40kw 400V ready,
- DC Generator 24 V 55 Amp loading.
- AC-Generator 16kw 400V running and produce electic power.
- The propeller works in both directions.
The next days we will fix some minor items.
- Most indicators are operational but not all.
- the main boats gear shift oil out the air overpressure
hole in the small stickhole drilled into the oil level indicator pipe stick.